[dpdk-dev] [PATCH 4/5] bond mode 4: allow external state machine
Pawel Wodkowski
pawelx.wodkowski at intel.com
Tue Apr 7 16:18:08 CEST 2015
On 2015-04-06 19:01, Eric Kinzie wrote:
Interesting patch. I will closer look at this tomorrow.
For now I have first comments:
> +static void bond_mode_8023ad_ext_periodic_cb(void *arg);
> +
> #ifdef RTE_LIBRTE_BOND_DEBUG_8023AD
> #define MODE4_DEBUG(fmt, ...) RTE_LOG(DEBUG, PMD, "%6u [Port %u: %s] " fmt, \
> bond_dbg_get_time_diff_ms(), slave_id, \
> @@ -1014,6 +1016,8 @@ bond_mode_8023ad_conf_get(struct rte_eth_dev *dev,
> conf->tx_period_ms = mode4->tx_period_timeout / ms_ticks;
> conf->update_timeout_ms = mode4->update_timeout_us / 1000;
> conf->rx_marker_period_ms = mode4->rx_marker_timeout / ms_ticks;
> + conf->slowrx_cb = mode4->slowrx_cb;
> + conf->external_sm = mode4->external_sm;
mode4->external_sm flag realy needed? Why do not use mode4->slowrx_cb as
external state machine indicator?
> }
>
> void
> @@ -1035,6 +1039,8 @@ bond_mode_8023ad_setup(struct rte_eth_dev *dev,
> conf->tx_period_ms = BOND_8023AD_TX_MACHINE_PERIOD_MS;
> conf->rx_marker_period_ms = BOND_8023AD_RX_MARKER_PERIOD_MS;
> conf->update_timeout_ms = BOND_MODE_8023AX_UPDATE_TIMEOUT_MS;
> + conf->slowrx_cb = NULL;
> + conf->external_sm = 0;
> }
>
> mode4->fast_periodic_timeout = conf->fast_periodic_ms * ms_ticks;
> @@ -1045,6 +1051,8 @@ bond_mode_8023ad_setup(struct rte_eth_dev *dev,
> mode4->tx_period_timeout = conf->tx_period_ms * ms_ticks;
> mode4->rx_marker_timeout = conf->rx_marker_period_ms * ms_ticks;
> mode4->update_timeout_us = conf->update_timeout_ms * 1000;
> + mode4->slowrx_cb = conf->slowrx_cb;
> + mode4->external_sm = conf->external_sm;
> }
>
> int
> @@ -1062,6 +1070,13 @@ bond_mode_8023ad_enable(struct rte_eth_dev *bond_dev)
> int
> bond_mode_8023ad_start(struct rte_eth_dev *bond_dev)
> {
> + struct bond_dev_private *internals = bond_dev->data->dev_private;
> + struct mode8023ad_private *mode4 = &internals->mode4;
> +
> + if (mode4->external_sm)
> + return rte_eal_alarm_set(BOND_MODE_8023AX_UPDATE_TIMEOUT_MS * 1000,
> + &bond_mode_8023ad_ext_periodic_cb, bond_dev);
> +
> return rte_eal_alarm_set(BOND_MODE_8023AX_UPDATE_TIMEOUT_MS * 1000,
> &bond_mode_8023ad_periodic_cb, bond_dev);
> }
> @@ -1069,6 +1084,13 @@ bond_mode_8023ad_start(struct rte_eth_dev *bond_dev)
> void
> bond_mode_8023ad_stop(struct rte_eth_dev *bond_dev)
> {
> + struct bond_dev_private *internals = bond_dev->data->dev_private;
> + struct mode8023ad_private *mode4 = &internals->mode4;
> +
> + if (mode4->external_sm) {
This is bad idea. If bond_mode_8023ad_setup will be called you might
have two handlers running for while. You should stop mode 4 by invoking
bond_mode_8023ad_stop() before you set mode4->external_sm and then, if
mode 4 was running, start it again.
Also, maybe a renaming "external_sm" to "state_machine_cb", set it to
against default one and using it without "if()" will simplify code. It
is no crucial but will eliminate couple of if's. In
rte_eth_bond_8023ad_ext_slowtx() you can compare it against default one.
> + rte_eal_alarm_cancel(&bond_mode_8023ad_ext_periodic_cb, bond_dev);
> + return;
> + }
> rte_eal_alarm_cancel(&bond_mode_8023ad_periodic_cb, bond_dev);
> }
>
> @@ -1215,3 +1237,156 @@ rte_eth_bond_8023ad_slave_info(uint8_t port_id, uint8_t slave_id,
> info->agg_port_id = port->aggregator_port_id;
> return 0;
> }
--
Pawel
More information about the dev
mailing list