[dpdk-dev] [PATCH 4/5] bond mode 4: allow external state machine

Pawel Wodkowski pawelx.wodkowski at intel.com
Tue Apr 7 16:18:08 CEST 2015


On 2015-04-06 19:01, Eric Kinzie wrote:

Interesting patch. I will closer look at this tomorrow.

For now I have first comments:

> +static void bond_mode_8023ad_ext_periodic_cb(void *arg);
> +
>   #ifdef RTE_LIBRTE_BOND_DEBUG_8023AD
>   #define MODE4_DEBUG(fmt, ...) RTE_LOG(DEBUG, PMD, "%6u [Port %u: %s] " fmt, \
>   			bond_dbg_get_time_diff_ms(), slave_id, \
> @@ -1014,6 +1016,8 @@ bond_mode_8023ad_conf_get(struct rte_eth_dev *dev,
>   	conf->tx_period_ms = mode4->tx_period_timeout / ms_ticks;
>   	conf->update_timeout_ms = mode4->update_timeout_us / 1000;
>   	conf->rx_marker_period_ms = mode4->rx_marker_timeout / ms_ticks;
> +	conf->slowrx_cb = mode4->slowrx_cb;
> +	conf->external_sm = mode4->external_sm;

mode4->external_sm flag realy needed? Why do not use mode4->slowrx_cb as 
external state machine indicator?

>   }
>
>   void
> @@ -1035,6 +1039,8 @@ bond_mode_8023ad_setup(struct rte_eth_dev *dev,
>   		conf->tx_period_ms = BOND_8023AD_TX_MACHINE_PERIOD_MS;
>   		conf->rx_marker_period_ms = BOND_8023AD_RX_MARKER_PERIOD_MS;
>   		conf->update_timeout_ms = BOND_MODE_8023AX_UPDATE_TIMEOUT_MS;
> +		conf->slowrx_cb = NULL;
> +		conf->external_sm = 0;
>   	}
>
>   	mode4->fast_periodic_timeout = conf->fast_periodic_ms * ms_ticks;
> @@ -1045,6 +1051,8 @@ bond_mode_8023ad_setup(struct rte_eth_dev *dev,
>   	mode4->tx_period_timeout = conf->tx_period_ms * ms_ticks;
>   	mode4->rx_marker_timeout = conf->rx_marker_period_ms * ms_ticks;
>   	mode4->update_timeout_us = conf->update_timeout_ms * 1000;
> +	mode4->slowrx_cb = conf->slowrx_cb;
> +	mode4->external_sm = conf->external_sm;
>   }
>
>   int
> @@ -1062,6 +1070,13 @@ bond_mode_8023ad_enable(struct rte_eth_dev *bond_dev)
>   int
>   bond_mode_8023ad_start(struct rte_eth_dev *bond_dev)
>   {
> +	struct bond_dev_private *internals = bond_dev->data->dev_private;
> +	struct mode8023ad_private *mode4 = &internals->mode4;
> +
> +	if (mode4->external_sm)
> +		return rte_eal_alarm_set(BOND_MODE_8023AX_UPDATE_TIMEOUT_MS * 1000,
> +			&bond_mode_8023ad_ext_periodic_cb, bond_dev);
> +
>   	return rte_eal_alarm_set(BOND_MODE_8023AX_UPDATE_TIMEOUT_MS * 1000,
>   			&bond_mode_8023ad_periodic_cb, bond_dev);
>   }
> @@ -1069,6 +1084,13 @@ bond_mode_8023ad_start(struct rte_eth_dev *bond_dev)
>   void
>   bond_mode_8023ad_stop(struct rte_eth_dev *bond_dev)
>   {
> +	struct bond_dev_private *internals = bond_dev->data->dev_private;
> +	struct mode8023ad_private *mode4 = &internals->mode4;
> +
> +	if (mode4->external_sm) {

This is bad idea. If bond_mode_8023ad_setup will be called you might 
have two handlers running for while. You should stop mode 4 by invoking 
bond_mode_8023ad_stop() before you set mode4->external_sm and then, if 
mode 4 was running, start it again.

Also, maybe a renaming "external_sm" to "state_machine_cb", set it to 
against default one and using it without "if()" will simplify code. It 
is no crucial but will eliminate couple of if's. In 
rte_eth_bond_8023ad_ext_slowtx() you can compare it against default one.

> +		rte_eal_alarm_cancel(&bond_mode_8023ad_ext_periodic_cb, bond_dev);
> +		return;
> +	}
>   	rte_eal_alarm_cancel(&bond_mode_8023ad_periodic_cb, bond_dev);
>   }
>
> @@ -1215,3 +1237,156 @@ rte_eth_bond_8023ad_slave_info(uint8_t port_id, uint8_t slave_id,
>   	info->agg_port_id = port->aggregator_port_id;
>   	return 0;
>   }

-- 
Pawel


More information about the dev mailing list