[dpdk-dev] [PATCH 2/2] app/testpmd: fix MAC endian issue in flow command

Adrien Mazarguil adrien.mazarguil at 6wind.com
Thu May 4 19:08:23 CEST 2017


MAC addresses are implicitly handled in network order since they are
actually byte strings, however this is not properly enforced with MAC masks
provided as prefix lengths, which end up inverted on little endian
systems.

Fixes: 6df81b325fa4 ("app/testpmd: add items eth/vlan to flow command")

Signed-off-by: Adrien Mazarguil <adrien.mazarguil at 6wind.com>
---
 app/test-pmd/cmdline_flow.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)

diff --git a/app/test-pmd/cmdline_flow.c b/app/test-pmd/cmdline_flow.c
index e952c91..0fd69f9 100644
--- a/app/test-pmd/cmdline_flow.c
+++ b/app/test-pmd/cmdline_flow.c
@@ -1057,13 +1057,13 @@ static const struct token token_list[] = {
 		.name = "dst",
 		.help = "destination MAC",
 		.next = NEXT(item_eth, NEXT_ENTRY(MAC_ADDR), item_param),
-		.args = ARGS(ARGS_ENTRY(struct rte_flow_item_eth, dst)),
+		.args = ARGS(ARGS_ENTRY_HTON(struct rte_flow_item_eth, dst)),
 	},
 	[ITEM_ETH_SRC] = {
 		.name = "src",
 		.help = "source MAC",
 		.next = NEXT(item_eth, NEXT_ENTRY(MAC_ADDR), item_param),
-		.args = ARGS(ARGS_ENTRY(struct rte_flow_item_eth, src)),
+		.args = ARGS(ARGS_ENTRY_HTON(struct rte_flow_item_eth, src)),
 	},
 	[ITEM_ETH_TYPE] = {
 		.name = "type",
@@ -2238,6 +2238,9 @@ parse_mac_addr(struct context *ctx, const struct token *token,
 	/* Bit-mask fill is not supported. */
 	if (arg->mask || size != sizeof(tmp))
 		goto error;
+	/* Only network endian is supported. */
+	if (!arg->hton)
+		goto error;
 	ret = cmdline_parse_etheraddr(NULL, str, &tmp, size);
 	if (ret < 0 || (unsigned int)ret != len)
 		goto error;
-- 
2.1.4



More information about the dev mailing list