Hi John,

> -----Original Message-----
> From: Mcnamara, John
> Sent: Monday, October 23, 2017 8:27 PM
> To: Lu, Wenzhuo <wenzhuo.lu at intel.com>; dev at dpdk.org
> Cc: Lu, Wenzhuo <wenzhuo.lu at intel.com>
> Subject: RE: [dpdk-dev] [PATCH] doc: how to set VF MAC address on ixgbe
> 
> 
> 
> > -----Original Message-----
> > From: dev [mailto:dev-bounces at dpdk.org] On Behalf Of Wenzhuo Lu
> > Sent: Monday, October 23, 2017 6:38 AM
> > To: dev at dpdk.org
> > Cc: Lu, Wenzhuo <wenzhuo.lu at intel.com>
> > Subject: [dpdk-dev] [PATCH] doc: how to set VF MAC address on ixgbe
> >
> > Add the description of how to add a MAC address for a VF from PF on
> ixgbe.
> >
> > Signed-off-by: Wenzhuo Lu <wenzhuo.lu at intel.com>
> > ---
> >  doc/guides/nics/ixgbe.rst | 11 +++++++++++
> >  1 file changed, 11 insertions(+)
> >
> > diff --git a/doc/guides/nics/ixgbe.rst b/doc/guides/nics/ixgbe.rst
> > index
> > 696ff69..bd0dc68 100644
> > --- a/doc/guides/nics/ixgbe.rst
> > +++ b/doc/guides/nics/ixgbe.rst
> > @@ -227,6 +227,17 @@ So when the user sets different MTUs on PF and
> VF
> > ports in one physical port,  the real MTU for all these PF and VF
> > ports is the largest value set.
> >  This behavior is based on the kernel driver behavior.
> >
> > +VF MAC address setting
> > +~~~~~~~~~~~~~~~~~~~~~~
> > +
> > +On ixgbe, the concept pool can be used for different things. It
> > +depends on the mode. In VMDq mode, the pool means a VMDq pool. In
> IOV
> > +mode, the pool means a VF.
> > +When setting the parameters of a pool, in VMDq mode, it's for a VMDq
> > +pool, in IOV mode, it's for a VF.
> > +There's no RTE API to add a VF's MAC address from PF. On ixgbe,
> > +there's a workaround to do it. "rte_eth_dev_mac_addr_add" also can be
> > +used to add a VF's MAC address.
> 
> I'd suggest something like the following may be a bit clearer:
> 
> VF MAC address setting
> ~~~~~~~~~~~~~~~~~~~~~~
> 
> On ixgbe, the concept of "pool" can be used for different things depending
> on the mode. In VMDq mode, "pool" means a VMDq pool. In IOV mode,
> "pool" means a VF.
> 
> There is no RTE API to add a VF's MAC address from the PF. On ixgbe, the
> ``rte_eth_dev_mac_addr_add()`` function can be can be used to add a VF's
> MAC address, as a workaround.
> 

Thanks for the suggestion. I'll send a V2.