[dpdk-dev] [PATCH 00/13] cxgbe: add CXGBE VF PMD and updates

Rahul Lakkireddy rahul.lakkireddy at chelsio.com
Wed Mar 28 11:29:12 CEST 2018


On Wednesday, March 03/28/18, 2018 at 14:00:58 +0530, Shahaf Shuler wrote:
> Wednesday, March 28, 2018 10:40 AM, Rahul Lakkireddy:
> > On Wednesday, March 03/28/18, 2018 at 10:19:17 +0530, Shahaf Shuler
> > >
> > > What exactly is the offload you try to expose? To strip the inner VLAN while
> > keeping the outer one?
> > >
> > 
> > Sorry about that, I should have provided more details on this earlier.
> > Chelsio hardware supports below for double-vlans:
> > 1) Dropping Outer VLAN in hw; inner vlan is stripped and available as packet
> > metadata.
> 
> So this is basically the DEV_RX_OFFLOAD_QINQ_STRIP with limitation from your device you cannot return the outer vlan in the packet metadata
> 

Since this is specific to Chelsio devices, is it better handled by
devargs approach instead? We will respin this particular patch
separately.
 
Hi Ferruh,
Should we re-post the entire series minus this particular patch?

> > 2) Preserving Outer VLAN so, Outer VLAN is stripped and available as packet
> > metadata. Inner VLAN is available as part of packet itself.
> 
> And this one is the regular DEV_RX_OFFLOAD_VLAN_STRIP
> 
> > 
> > So, the configurability here is with respect to Outer VLAN and subsequently
> > what is available as part of packet metadata (outer or inner vlan).  Inner
> > VLAN gets retained in both cases.  However, based on how Outer VLAN is
> > configured, Inner VLAN will be available either as packet metadata or as part
> > of packet itself.
> > 
> > We are not very sure if DEV_RX_OFFLOAD_QINQ_STRIP could be used here.
> > If it holds the same meaning then we will use the same.
> 
> Yeah , we are missing good documentation of what each offload means. 
> > 
> > Thanks,
> > Rahul


More information about the dev mailing list