[dpdk-dev] [PATCH v2] examples/power: add baseline mode to PMD power

Burakov, Anatoly anatoly.burakov at intel.com
Wed Jun 23 16:14:43 CEST 2021


On 23-Jun-21 1:09 PM, David Hunt wrote:
> 
> On 23/6/2021 11:14 AM, Burakov, Anatoly wrote:
>> On 22-Jun-21 3:07 PM, David Hunt wrote:
>>> The PMD Power Management scheme currently has 3 modes,
>>> scale, monitor and pause. However, it would be nice to
>>> have a baseline mode for easy comparison of power savings
>>> with and without these modes.
>>>
>>> This patch adds a 'baseline' mode were the pmd power
>>> management is not enabled. Use --pmg-mgmt=baseline.
>>>
>>> Signed-off-by: David Hunt <david.hunt at intel.com>
>>>
>>> ---
>>> changes in v2
>>> * added a bool for baseline mode rather than abusing enums
>>> ---
>>>   examples/l3fwd-power/main.c | 14 ++++++++++++--
>>>   1 file changed, 12 insertions(+), 2 deletions(-)
>>>
>>> diff --git a/examples/l3fwd-power/main.c b/examples/l3fwd-power/main.c
>>> index f8dfed1634..aeb2411e62 100644
>>> --- a/examples/l3fwd-power/main.c
>>> +++ b/examples/l3fwd-power/main.c
>>> @@ -207,6 +207,7 @@ enum appmode {
>>>   enum appmode app_mode;
>>>     static enum rte_power_pmd_mgmt_type pmgmt_type;
>>> +bool baseline_enabled;
>>>     enum freq_scale_hint_t
>>>   {
>>> @@ -1617,7 +1618,7 @@ print_usage(const char *prgname)
>>>           " empty polls, full polls, and core busyness to telemetry\n"
>>>           " --interrupt-only: enable interrupt-only mode\n"
>>>           " --pmd-mgmt MODE: enable PMD power management mode. "
>>> -        "Currently supported modes: monitor, pause, scale\n",
>>> +        "Currently supported modes: baseline, monitor, pause, scale\n",
>>>           prgname);
>>>   }
>>>   @@ -1714,6 +1715,7 @@ parse_pmd_mgmt_config(const char *name)
>>>   #define PMD_MGMT_MONITOR "monitor"
>>>   #define PMD_MGMT_PAUSE   "pause"
>>>   #define PMD_MGMT_SCALE   "scale"
>>> +#define PMD_MGMT_BASELINE  "baseline"
>>>         if (strncmp(PMD_MGMT_MONITOR, name, sizeof(PMD_MGMT_MONITOR)) 
>>> == 0) {
>>>           pmgmt_type = RTE_POWER_MGMT_TYPE_MONITOR;
>>> @@ -1729,6 +1731,10 @@ parse_pmd_mgmt_config(const char *name)
>>>           pmgmt_type = RTE_POWER_MGMT_TYPE_SCALE;
>>>           return 0;
>>>       }
>>> +    if (strncmp(PMD_MGMT_BASELINE, name, sizeof(PMD_MGMT_BASELINE)) 
>>> == 0) {
>>> +        baseline_enabled = true;
>>> +        return 0;
>>> +    }
>>>       /* unknown PMD power management mode */
>>>       return -1;
>>>   }
>>> @@ -2528,6 +2534,9 @@ main(int argc, char **argv)
>>>       /* init RTE timer library to be used late */
>>>       rte_timer_subsystem_init();
>>>   +    /* if we're running pmd-mgmt mode, don't default to baseline 
>>> mode */
>>> +    baseline_enabled = false;
>>> +
>>>       /* parse application arguments (after the EAL ones) */
>>>       ret = parse_args(argc, argv);
>>>       if (ret < 0)
>>> @@ -2767,7 +2776,8 @@ main(int argc, char **argv)
>>>                            "Fail to add ptype cb\n");
>>>               }
>>>   -            if (app_mode == APP_MODE_PMD_MGMT) {
>>> +            if ((app_mode == APP_MODE_PMD_MGMT) &&
>>> +                    (baseline_enabled == false)) {
>>
>> Nitpicking, !baseline_enabled
>>
> Thanks, Anatoly. I don't feel a re-spin is needed for this, but I'll 
> take this format into consideration for future patches, OK?

Yep, i'm fine either way. Maybe someone can fix it on apply :)

> 
> 
>> Otherwise,
>>
>> Acked-by: Anatoly Burakov <anatoly.burakov at intel.com>
>>
>>


-- 
Thanks,
Anatoly


More information about the dev mailing list