[dts] [PATCH v2] test_plans: add large packet payload check for vm2vm_virtio_pmd_test_plan
Yinan
yinan.wang at intel.com
Tue Jun 18 02:39:47 CEST 2019
From: Wang Yinan <yinan.wang at intel.com>
Signed-off-by: Wang Yinan <yinan.wang at intel.com>
---
test_plans/vm2vm_virtio_pmd_test_plan.rst | 24 +++++++++++------------
1 file changed, 12 insertions(+), 12 deletions(-)
diff --git a/test_plans/vm2vm_virtio_pmd_test_plan.rst b/test_plans/vm2vm_virtio_pmd_test_plan.rst
index 3666751..bb9fc21 100644
--- a/test_plans/vm2vm_virtio_pmd_test_plan.rst
+++ b/test_plans/vm2vm_virtio_pmd_test_plan.rst
@@ -78,8 +78,8 @@ Test Case 1: VM2VM vhost-user/virtio-pmd with mergeable path
3. On VM1, bind vdev with igb_uio driver,then run testpmd, set rxonly mode for virtio1::
./testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txd=1024 --rxd=1024
- testpmd>set fwd rxonly
- testpmd>start
+ testpmd>set fwd rxonly
+ testpmd>start
4. On VM2, bind vdev with igb_uio driver,then run testpmd, set txonly for virtio2 and send 64B packets::
@@ -129,8 +129,8 @@ Test Case 2: VM2VM vhost-user/virtio-pmd with vector path
3. On VM1, bind vdev with igb_uio driver,then run testpmd, set rxonly for virtio1::
./testpmd -c 0x3 -n 4 -- -i --txd=1024 --rxd=1024
- testpmd>set fwd rxonly
- testpmd>start
+ testpmd>set fwd rxonly
+ testpmd>start
4. On VM2, bind vdev with igb_uio driver,then run testpmd, set txonly for virtio2 and send 64B packets::
@@ -180,8 +180,8 @@ Test Case 3: VM2VM vhost-user/virtio-pmd with normal path
3. On VM1, bind vdev with igb_uio driver,then run testpmd, set rxonly for virtio1 ::
./testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txd=1024 --rxd=1024
- testpmd>set fwd rxonly
- testpmd>start
+ testpmd>set fwd rxonly
+ testpmd>start
4. On VM2, bind vdev with igb_uio driver,then run testpmd, set rxonly for virtio2 and send 64B packets ::
@@ -231,8 +231,8 @@ Test Case 4: VM2VM vhost-user/virtio1.0-pmd with mergeable path
3. On VM1, bind vdev with igb_uio driver,then run testpmd, set rxonly for virtio1 ::
./testpmd -c 0x3 -n 4 -- -i --tx-offloads=0x00 --enable-hw-vlan-strip --txd=1024 --rxd=1024
- testpmd>set fwd rxonly
- testpmd>start
+ testpmd>set fwd rxonly
+ testpmd>start
4. On VM2, bind vdev with igb_uio driver,then run testpmd, set txonly for virtio2 ::
@@ -292,8 +292,8 @@ Test Case 5: VM2VM vhost-user/virtio-pmd mergeable path with payload valid check
4. Bind virtio with igb_uio driver,then run testpmd, set rxonly mode for virtio-pmd on VM1::
./testpmd -c 0x3 -n 4 --file-prefix=test -- -i --txd=1024 --rxd=1024 --max-pkt-len=9600
- testpmd>set fwd rxonly
- testpmd>start
+ testpmd>set fwd rxonly
+ testpmd>start
5. Bootup pdump in VM1::
@@ -355,8 +355,8 @@ Test Case 6: VM2VM vhost-user/virtio1.0-pmd mergeable path with payload valid ch
4. Bind virtio with igb_uio driver,then run testpmd, set rxonly mode for virtio-pmd on VM1::
./testpmd -c 0x3 -n 4 --file-prefix=test -- -i --txd=1024 --rxd=1024 --max-pkt-len=9600
- testpmd>set fwd rxonly
- testpmd>start
+ testpmd>set fwd rxonly
+ testpmd>start
5. Bootup pdump in VM1::
--
2.17.1