[dts] [PATCH V1] test_plans: fix build warning

Tu, Lijuan lijuan.tu at intel.com
Wed May 29 04:36:12 CEST 2019


Applied, thanks

> -----Original Message-----
> From: dts [mailto:dts-bounces at dpdk.org] On Behalf Of Wenjie Li
> Sent: Wednesday, May 22, 2019 6:51 PM
> To: dts at dpdk.org
> Cc: Li, WenjieX A <wenjiex.a.li at intel.com>
> Subject: [dts] [PATCH V1] test_plans: fix build warning
> 
> From: "Wenjie Li" <wenjiex.a.li at intel.com>
> 
> fix build warning of test plans
> 
> Signed-off-by: Wenjie Li <wenjiex.a.li at intel.com>
> ---
>  test_plans/dpdk_gro_lib_test_plan.rst         | 36 +++++++++++++------
>  test_plans/dpdk_gso_lib_test_plan.rst         | 16 ++++++---
>  test_plans/macsec_for_ixgbe_test_plan.rst     | 14 ++++----
>  test_plans/vf_l3fwd_test_plan.rst             |  4 +--
>  .../vhost_dequeue_zero_copy_test_plan.rst     |  4 ++-
>  5 files changed, 50 insertions(+), 24 deletions(-)
> 
> diff --git a/test_plans/dpdk_gro_lib_test_plan.rst
> b/test_plans/dpdk_gro_lib_test_plan.rst
> index 4ca78ef..410ae68 100644
> --- a/test_plans/dpdk_gro_lib_test_plan.rst
> +++ b/test_plans/dpdk_gro_lib_test_plan.rst
> @@ -87,7 +87,9 @@ Modify the testpmd code as following::
>  Test flow
>  =========
> 
> -NIC2(In kernel) -> NIC1(DPDK) -> testpmd(csum fwd) -> Vhost -> Virtio-net
> +::
> +
> +  NIC2(In kernel) -> NIC1(DPDK) -> testpmd(csum fwd) -> Vhost ->
> + Virtio-net
> 
>  Test Case1: DPDK GRO lightmode test with tcp/ipv4 traffic
> =========================================================
> @@ -119,7 +121,9 @@ Test Case1: DPDK GRO lightmode test with tcp/ipv4
> traffic
>      testpmd>port start 1
>      testpmd>start
> 
> -3.  Set up vm with virto device and using kernel virtio-net driver::
> +3.  Set up vm with virto device and using kernel virtio-net driver:
> +
> +  ::
> 
>      taskset -c 13 \
>      qemu-system-x86_64 -name us-vhost-vm1 \ @@ -172,7 +176,9 @@ Test
> Case2: DPDK GRO heavymode test with tcp/ipv4 traffic
>      testpmd>port start 1
>      testpmd>start
> 
> -3.  Set up vm with virto device and using kernel virtio-net driver::
> +3.  Set up vm with virto device and using kernel virtio-net driver:
> +
> +  ::
> 
>      taskset -c 13 \
>      qemu-system-x86_64 -name us-vhost-vm1 \ @@ -225,7 +231,9 @@ Test
> Case3: DPDK GRO heavymode_flush4 test with tcp/ipv4 traffic
>      testpmd>port start 1
>      testpmd>start
> 
> -3.  Set up vm with virto device and using kernel virtio-net driver::
> +3.  Set up vm with virto device and using kernel virtio-net driver:
> +
> +  ::
> 
>      taskset -c 13 \
>      qemu-system-x86_64 -name us-vhost-vm1 \ @@ -253,11 +261,15 @@
> Test Case4: DPDK GRO test with vxlan traffic
> 
>  Vxlan topology
>  --------------
> -  VM          Host
> -50.1.1.2      50.1.1.1
> -   |           |
> -1.1.2.3       1.1.2.4
> -   |------------Testpmd------------|
> +
> +::
> +
> +    VM          Host
> +  50.1.1.2      50.1.1.1
> +     |           |
> +  1.1.2.3       1.1.2.4
> +     |------------Testpmd------------|
> +
> 
>  1. Connect two nic port directly, put nic2 into another namesapce and
> create Host VxLAN port::
> 
> @@ -296,7 +308,9 @@ Vxlan topology
>      testpmd>port start 1
>      testpmd>start
> 
> -3.  Set up vm with virto device and using kernel virtio-net driver::
> +3.  Set up vm with virto device and using kernel virtio-net driver:
> +
> +  ::
> 
>      taskset -c 13 \
>      qemu-system-x86_64 -name us-vhost-vm1 \ @@ -321,4 +335,4 @@ Vxlan
> topology  5. Start iperf test, run iperf server at vm side and iperf client at
> host side, check throughput in log::
> 
>      Host side :  ip netns exec t2 iperf -c 50.1.1.2 -i 2 -t 60 -f g -m
> -    VM side:     iperf -s -f g
> +    VM side:     iperf -s -f g
> \ No newline at end of file
> diff --git a/test_plans/dpdk_gso_lib_test_plan.rst
> b/test_plans/dpdk_gso_lib_test_plan.rst
> index e88cff7..8de5f56 100644
> --- a/test_plans/dpdk_gso_lib_test_plan.rst
> +++ b/test_plans/dpdk_gso_lib_test_plan.rst
> @@ -81,7 +81,9 @@ Modify the testpmd code as following::
>  Test flow
>  =========
> 
> -NIC2(In kernel) <- NIC1(DPDK) <- testpmd(csum fwd) <- Vhost <- Virtio-net
> +::
> +
> +  NIC2(In kernel) <- NIC1(DPDK) <- testpmd(csum fwd) <- Vhost <-
> + Virtio-net
> 
>  Test Case1: DPDK GSO test with tcp traffic
> ==========================================
> @@ -109,7 +111,9 @@ Test Case1: DPDK GSO test with tcp traffic
>      testpmd>port start 0
>      testpmd>start
> 
> -3.  Set up vm with virto device and using kernel virtio-net driver::
> +3.  Set up vm with virto device and using kernel virtio-net driver:
> +
> +  ::
> 
>      taskset -c 13 \
>      qemu-system-x86_64 -name us-vhost-vm1 \ @@ -169,7 +173,9 @@ Test
> Case3: DPDK GSO test with vxlan traffic
>      testpmd>port start 0
>      testpmd>start
> 
> -3.  Set up vm with virto device and using kernel virtio-net driver::
> +3.  Set up vm with virto device and using kernel virtio-net driver:
> +
> +  ::
> 
>      taskset -c 13 \
>      qemu-system-x86_64 -name us-vhost-vm1 \ @@ -221,7 +227,9 @@ Test
> Case4: DPDK GSO test with gre traffic
>      testpmd>port start 0
>      testpmd>start
> 
> -3.  Set up vm with virto device and using kernel virtio-net driver::
> +3.  Set up vm with virto device and using kernel virtio-net driver:
> +
> +  ::
> 
>      taskset -c 13 \
>      qemu-system-x86_64 -name us-vhost-vm1 \ diff --git
> a/test_plans/macsec_for_ixgbe_test_plan.rst
> b/test_plans/macsec_for_ixgbe_test_plan.rst
> index 893e7a6..79b7d57 100644
> --- a/test_plans/macsec_for_ixgbe_test_plan.rst
> +++ b/test_plans/macsec_for_ixgbe_test_plan.rst
> @@ -73,12 +73,14 @@ Prerequisites
>  1. Hardware:
> 
>     * 1x Niantic NIC (2x 10G)
> -     port0:
> -       pci address: 07:00.0
> -       mac address: 00:00:00:00:00:01
> -     port1:
> -       pci address: 07:00.1
> -       mac address: 00:00:00:00:00:02
> +     ::
> +
> +       port0:
> +         pci address: 07:00.0
> +         mac address: 00:00:00:00:00:01
> +       port1:
> +         pci address: 07:00.1
> +         mac address: 00:00:00:00:00:02
> 
>     * 2x IXIA ports (10G)
> 
> diff --git a/test_plans/vf_l3fwd_test_plan.rst
> b/test_plans/vf_l3fwd_test_plan.rst
> index 97e3ab7..9260cb0 100644
> --- a/test_plans/vf_l3fwd_test_plan.rst
> +++ b/test_plans/vf_l3fwd_test_plan.rst
> @@ -89,7 +89,7 @@ Setup overview
>  Set up topology as above based on the NIC used.
> 
>  Test Case 1: Measure performance with kernel PF & dpdk VF -
> ========================================================
> +=========================================================
> 
>  1, Bind PF ports to kernel driver, i40e or ixgbe, then create 1 VF from each PF,
> take XL710 for example::
> @@ -132,7 +132,7 @@ Fill out this table with results.
> 
> 
>  Test Case 2: Measure performance with dpdk PF & dpdk VF -
> ======================================================
> +=======================================================
> 
>  1, Bind PF ports to igb_uio driver, then create 1 VF from each PF,  take XL710
> for example::
> diff --git a/test_plans/vhost_dequeue_zero_copy_test_plan.rst
> b/test_plans/vhost_dequeue_zero_copy_test_plan.rst
> index 3ec5e53..3c74c77 100644
> --- a/test_plans/vhost_dequeue_zero_copy_test_plan.rst
> +++ b/test_plans/vhost_dequeue_zero_copy_test_plan.rst
> @@ -323,7 +323,9 @@ Test topology: NIC2(In kernel) <- NIC1(DPDK) <-
> testpmd(csum fwd) <- Vhost <- Vi
>      testpmd>port start 0
>      testpmd>start
> 
> -3.  Set up vm with virto device and using kernel virtio-net driver::
> +3.  Set up vm with virto device and using kernel virtio-net driver:
> +
> +  ::
> 
>      taskset -c 13 \
>      qemu-system-x86_64 -name us-vhost-vm1 \
> --
> 2.17.2



More information about the dts mailing list