[dts] [PATCH V1 1/2] test_plans/rxtx_offload_test_plan: adapt to CVL NIC
xiewei
weix.xie at intel.com
Wed Mar 31 18:47:26 CEST 2021
for ice NIC, it failed to enable mbuf_fast_free per_queue.
Signed-off-by: xiewei <weix.xie at intel.com>
---
test_plans/rxtx_offload_test_plan.rst | 14 ++++++++++++++
1 file changed, 14 insertions(+)
diff --git a/test_plans/rxtx_offload_test_plan.rst b/test_plans/rxtx_offload_test_plan.rst
index 246e1e16..b107aba7 100644
--- a/test_plans/rxtx_offload_test_plan.rst
+++ b/test_plans/rxtx_offload_test_plan.rst
@@ -643,6 +643,20 @@ Test case: FVL Tx offload per-queue setting
The port fwd can be started normally.
+Note:
+
+But for ice NIC, it failed to enable mbuf_fast_free per_queue::
+
+ testpmd> port stop 0
+ testpmd> port 0 txq 0 tx_offload mbuf_fast_free on
+ testpmd> port 0 txq 1 tx_offload mbuf_fast_free on
+ testpmd> port 0 txq 2 tx_offload mbuf_fast_free on
+ testpmd> port 0 txq 3 tx_offload mbuf_fast_free on
+ testpmd> port start 0
+ Configuring Port 0 (socket 0)
+ Ethdev port_id=0 tx_queue_id=0, new added offloads 0x10000 must be within per-queue offload capabilities 0x0 in rte_eth_tx_queue_setup()
+ Fail to configure port 0 tx queues
+
4. Disable mbuf_fast_free per_queue::
testpmd> port stop 0
--
2.17.1
More information about the dts