[PATCH] net/mlx5: fix GCC uninitialized variable warning

Dmitry Kozlyuk dkozlyuk at nvidia.com
Tue Dec 28 10:17:03 CET 2021


When building with -Db_sanitize=thread, GCC gives a warning:

drivers/net/mlx5/mlx5_flow_meter.c: In function ‘mlx5_flow_meter_create’:
drivers/net/mlx5/mlx5_flow_meter.c:1170:33: warning: ‘legacy_fm’ may be
    used uninitialized in this function [-Wmaybe-uninitialized]

This is a false-positive: legacy_fm is initialized and used
if and only if priv->sh->meter_aso_en is false.
Work around this by initializing legacy_fm to NULL.
Add an assertion before legacy_fm use in case the logic changes.

Fixes: 444320186393 ("net/mlx5: support meter creation with policy")
Cc: lizh at nvidia.com
Cc: stable at dpdk.org

Reported-by: Stephen Hemminger <stephen at networkplumber.org>
Signed-off-by: Dmitry Kozlyuk <dkozlyuk at nvidia.com>
Acked-by: Matan Azrad <matan at nvidia.com>
---
 drivers/net/mlx5/mlx5_flow_meter.c | 7 +++++--
 1 file changed, 5 insertions(+), 2 deletions(-)

diff --git a/drivers/net/mlx5/mlx5_flow_meter.c b/drivers/net/mlx5/mlx5_flow_meter.c
index f4a7b697e6..fd4f286deb 100644
--- a/drivers/net/mlx5/mlx5_flow_meter.c
+++ b/drivers/net/mlx5/mlx5_flow_meter.c
@@ -1167,7 +1167,8 @@ mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
 	struct mlx5_legacy_flow_meters *fms = &priv->flow_meters;
 	struct mlx5_flow_meter_profile *fmp;
 	struct mlx5_flow_meter_info *fm;
-	struct mlx5_legacy_flow_meter *legacy_fm;
+	/* GCC fails to infer legacy_fm is set when !priv->sh->meter_aso_en. */
+	struct mlx5_legacy_flow_meter *legacy_fm = NULL;
 	struct mlx5_flow_meter_policy *mtr_policy = NULL;
 	struct mlx5_indexed_pool_config flow_ipool_cfg = {
 		.size = 0,
@@ -1273,8 +1274,10 @@ mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
 	if (mlx5_flow_create_mtr_tbls(dev, fm, mtr_idx, domain_bitmap))
 		goto error;
 	/* Add to the flow meter list. */
-	if (!priv->sh->meter_aso_en)
+	if (!priv->sh->meter_aso_en) {
+		MLX5_ASSERT(legacy_fm != NULL);
 		TAILQ_INSERT_TAIL(fms, legacy_fm, next);
+	}
 	/* Add to the flow meter list. */
 	fm->active_state = 1; /* Config meter starts as active. */
 	fm->is_enable = 1;
-- 
2.25.1