[PATCH v3 2/2] net/hns3: add FDIR VLAN match mode runtime config
Ferruh Yigit
ferruh.yigit at amd.com
Thu Jun 29 17:52:49 CEST 2023
On 6/29/2023 2:21 PM, Dongdong Liu wrote:
> diff --git a/doc/guides/nics/hns3.rst b/doc/guides/nics/hns3.rst
> index 5373ec5a8f..001ccbdb62 100644
> --- a/doc/guides/nics/hns3.rst
> +++ b/doc/guides/nics/hns3.rst
> @@ -140,6 +140,32 @@ Runtime Configuration
> For example::
> -a 0000:7d:00.0,mbx_time_limit_ms=600
>
> +- ``fdir_vlan_match_mode`` (default ``strict``)
> +
> + Used to select VLAN match mode. This runtime config can be ``strict``
> + or ``nostrict`` and is only valid for PF devices.
> + If driver works on ``strict`` mode (default mode), hardware does strictly
> + match the input flow base on VLAN number.
> +
> + For the following scenarios with two rules:
> +
> + .. code-block:: console
> +
> + rule0:
> + pattern: eth type is 0x0806
> + actions: queue index 3
> + rule1:
> + pattern: eth type is 0x0806 / vlan vid is 20
> + actions: queue index 4
> +
> + If application select ``strict`` mode, only the ARP packets with VLAN
> + 20 are directed to queue 4, and the ARP packets with other VLAN ID
> + cannot be directed to the specified queue. If application want to all
> + ARP packets with or without VLAN to be directed to the specified queue,
> + application can select ``nostrict`` mode and just need to set rule0.
> +
> + For example::
> + -a 0000:7d:00.0,fdir_vlan_match_mode=nostrict>
'::' doesn't provide pre-formatted text without an empty line after it,
I will fix this while merging, but other device argument documentations
have same problem, can you please send a patch to fix it?