[dpdk-users] Low TX performance on Mellanox ConnectX-3 NIC

Jesper Wramberg jesper.wramberg at gmail.com
Mon Nov 2 13:57:05 CET 2015


Hey,

As a follow-up I tried changing interrupts around without any changes to
achieved speed.
Lastly, after some iperf testing using 10 threads it would seem that it is
impossible to achieve over 10G BW.

Got an interesting output from "perf top -p <pid>" however while running
the raw_ethernet_bw script.

  37.22%  libpthread-2.17.so  [.] pthread_spin_lock
  10.00%  libmlx4-rdmav2.so   [.] 0x000000000000b05a
   1.20%  libmlx4-rdmav2.so   [.] 0x000000000000b3ec
   1.07%  libmlx4-rdmav2.so   [.] 0x000000000000b06c
   1.07%  libmlx4-rdmav2.so   [.] 0x000000000000afc0
   1.06%  raw_ethernet_bw     [.] 0x000000000001484f
   1.06%  raw_ethernet_bw     [.] 0x0000000000014869
   1.06%  raw_ethernet_bw     [.] 0x00000000000142ec
   1.05%  libmlx4-rdmav2.so   [.] 0x000000000000b41c
   1.05%  libmlx4-rdmav2.so   [.] 0x000000000000aff6
   1.05%  raw_ethernet_bw     [.] 0x0000000000014f09
   1.03%  libmlx4-rdmav2.so   [.] 0x0000000000005a60
   1.03%  libmlx4-rdmav2.so   [.] 0x000000000000be51
   1.03%  libpthread-2.17.so  [.] pthread_spin_unlock
   1.01%  libmlx4-rdmav2.so   [.] 0x000000000000afdc
   1.00%  libmlx4-rdmav2.so   [.] 0x000000000000b042
   1.00%  raw_ethernet_bw     [.] 0x0000000000014314
   0.98%  libmlx4-rdmav2.so   [.] 0x000000000000bf38
   0.97%  libmlx4-rdmav2.so   [.] 0x000000000000b3d2
   0.97%  raw_ethernet_bw     [.] 0x00000000000142a4
   0.96%  raw_ethernet_bw     [.] 0x0000000000014282
   0.96%  libmlx4-rdmav2.so   [.] 0x000000000000b415
   0.96%  raw_ethernet_bw     [.] 0x000000000001425e

I wonder if the tool is supposed to spend so much time in
pthread_spin_lock..

Best regards,
Jesper

2015-11-02 11:59 GMT+01:00 Jesper Wramberg <jesper.wramberg at gmail.com>:

> Hi again,
>
> Thank you for your input. I have now switched to using the raw_ethernet_bw
> script as transmitter and the test-pmd as receiver. An immediate result I
> discovered was that the raw_ethernet_bw tool achieves very similar TX
> performance as my DPDK transmitter.
>
>
> (note both cpu10 and mlx4_0 is on same numa node as wanted)
> taskset -c 10 raw_ethernet_bw --client -d mlx4_0 -i 2 -l 3 --duration 20
> -s 1480 --dest_mac F4:52:14:7A:59:80
>
> ---------------------------------------------------------------------------------------
> Post List requested - CQ moderation will be the size of the post list
>
> ---------------------------------------------------------------------------------------
>                     Send Post List BW Test
>  Dual-port       : OFF          Device         : mlx4_0
>  Number of qps   : 1            Transport type : IB
>  Connection type : RawEth               Using SRQ      : OFF
>  TX depth        : 128
>  Post List       : 3
>  CQ Moderation   : 3
>  Mtu             : 1518[B]
>  Link type       : Ethernet
>  Gid index       : 0
>  Max inline data : 0[B]
>  rdma_cm QPs     : OFF
>  Data ex. method : Ethernet
>
> ---------------------------------------------------------------------------------------
> **raw ethernet header****************************************
>
> --------------------------------------------------------------
> | Dest MAC         | Src MAC          | Packet Type          |
> |------------------------------------------------------------|
> | F4:52:14:7A:59:80| E6:1D:2D:11:FF:41|DEFAULT               |
> |------------------------------------------------------------|
>
>
> ---------------------------------------------------------------------------------------
>  #bytes     #iterations    BW peak[MB/sec]    BW average[MB/sec]
> MsgRate[Mpps]
>  1480       33242748         0.00               4691.58            3.323974
>
> ---------------------------------------------------------------------------------------
>
>
> Running it with the 64 byte packets Olga specified gives me the following
> result:
>
>
> ---------------------------------------------------------------------------------------
>  #bytes     #iterations    BW peak[MB/sec]    BW average[MB/sec]
> MsgRate[Mpps]
>  64         166585650        0.00               1016.67
>  16.657163
>
> ---------------------------------------------------------------------------------------
>
>
> The results are the same with and without flow control. I have followed
> the Mellanox DPDK QSG and done everything in the performance section
> (except the things regarding interrupts).
>
> So to answer Olga's questions :-)
>
> 1: Unfortunately I can't. If I try the FW update complains since the cards
> came with Dell configuration (PSID: DEL0A70000023).
>
> 2: In my final setup I need jumboframes but just for the sake of testing I
> tried changing CONFIG_RTE_LIBRTE_MLX4_SGE_WR_N to 1 in the DPDK config.
> This did not really change anything, neither in my initial setup nor the
> one described above.
>
> 3: In the final setup, I plan to share the NICs between multiple
> independent processes. For this reason, I wanted to use SR-IOV and
> whitelist a single VF to each process. Anyway, for the tests above I have
> used the PFs for simplicity.
> (Side note: I discovered that multiple DPDK instances can use the same PCI
> address which might eliminate the need for SR-IOV. I wonder how that works
> :-))
>
> So conclusively, isn't the raw_ethernet_bw tool supposed to have larger
> output BW with 1480 byte packets ?
>
> I have a sysinfo dump using the Mellanox sysinfo-snapshot.py script. I can
> mail this to anyone who have the time to look further into it.
>
> Thank you for your help, best regards
> Jesper
>
> 2015-11-01 11:05 GMT+01:00 Olga Shern <olgas at mellanox.com>:
>
>> Hi Jesper,
>>
>> Several suggestions,
>> 1.      Any chance you can install latest FW from Mellanox web site or
>> the one that is included in OFED 3.1 version that you have downloaded?  The
>> latest version is  2.35.5100.
>> 2.      Please configure SGE_NUM=1 in DPDK config file  in case you don't
>> need jumbo frames. This will improve performance.
>> 3.      Not clear from your description, if you are running DPDK on VM ?
>> Are you suing SRIOV ?
>> 4.      I suggest you  to run  first,  testpmd application. The traffic
>> generator can be raw_ethernet_bw application that coming with MLNX_OFED, it
>> can generate L2, IPV4 and TCP/UDP packets
>>         For example:  taskset -c 10 raw_ethernet_bw --client -d mlx4_0 -i
>> 1 -l 3 --duration 10 -s 64 --dest_mac F4:52:14:7A:59:80 &
>>         This will send L2 packets via mlx4_0 NIC port 1 , packet size =
>> 64, for 10 sec, batch = 3 (-l)
>>         You can see according to testpmd counters the performance.
>>
>> Please check Mellanox community  posts, I think they can help you.
>> https://community.mellanox.com/docs/DOC-1502
>>
>> We also have performance suggestions in our QSG:
>>
>> http://www.mellanox.com/related-docs/prod_software/MLNX_DPDK_Quick_Start_Guide_v2%201_1%201.pdf
>>
>> Best Regards,
>> Olga
>>
>>
>> Objet : [dpdk-users] Low TX performance on Mellanox ConnectX-3 NIC Date :
>> samedi 31 octobre 2015, 09:54:04 De : Jesper Wramberg <
>> jesper.wramberg at gmail.com>  À : users at dpdk.org
>>
>> Hi all,
>>
>>
>>
>> I am experiencing some performance issues in a somewhat custom setup with
>> two Mellanox ConnectX-3 NICs. I realize these issues might be due to the
>> setup, but I was hoping someone might be able to pinpoint some possible
>> problems/bottlenecks.
>>
>>
>>
>>
>> The server:
>>
>> I have a Dell PowerEdge R630 with two Mellanox ConnectX-3 NICs (one on
>> each socket). I have a minimal Centos 7.1.1503 installed with kernel-
>> 3.10.0-229.
>> Note that this kernel is re-build with most things disabled to minimize
>> size, etc. It has infiniband enabled, however, and mlx4_core as a module
>> (since nothing works otherwise). Finally, I have connected the two NICs
>> from port 2 to port 2.
>>
>>
>>
>> The firmware:
>>
>> I have installed the latest firmware for the NICs from dell which is
>> 2.34.5060.
>>
>>
>>
>> The drivers, modules, etc.:
>>
>> I have downloaded the Mellanox OFED package 3.1 for Centos 7.1 and used
>> its rebuild feature to build it against the custom kernel. I have installed
>> it using the --basic option since I just want libibverbs, libmlx4, kernel
>> modules and openibd service stuff. The mlx4_core.conf is set for ethernet
>> on all ports. Moreover, it is configured for flow steering mode -7 and a
>> few VFs. I can restart the openibd service successfully and everything
>> seems to be working. ibdev2netdev reports the NICs and its VFs, etc. The
>> only problems I have encountered at this stage is that the links doesn't
>> always seem to come up unless I unplug and re-plug the cables.
>>
>>
>>
>> DPDK setup:
>>
>> I have built DPDK with the mlx4 pmd using the .h/.a files from the OFED
>> package. I build it using the default values for everything. Running the
>> simple hello world example I can see that everything is initialized
>> correctly, etc.
>>
>>
>>
>> Test setup:
>>
>> To test the performance of the NICs I have the following setup. Two
>> processes, P1 and P2, running on NIC A. Two other processes, P3 and P4,
>> running on NIC B. All processes use virtual functions on their respective
>> NICs. Depending on the test, the processes can either transmit or receive
>> data. To transmit, I use a simple DPDK program which generates 32000
>> packets and transmits them over and over until it has sent 640 million
>> packets. Similarly, I use a simple DPDK program to receive which is
>> basically the layer 2 forwarding example without re-transmission.
>>
>>
>>
>> First test:
>>
>> In my first test, P1 transmits data to P3 while the other processes are
>> idle.
>>
>> Packet size: 1480 byte packets
>>
>> Flow control: On/Off, doesn’t matter I get same result.
>>
>> Result: P3 receive all packets but it takes 192.52 seconds ~ 3.32 Mpps ~
>> 4.9Gbit/s
>>
>>
>>
>> Second test:
>>
>> I my second test, I attempt to increase the amount of data transmitted
>> over NIC A. As such, P1 transmits data to P3 while P2 transmits data to P4.
>>
>> Packet size: 1480 byte packets
>>
>> Flow control: On/Off, doesn’t matter I get same result.
>>
>> Results: P3 and P4 receive all packets but it takes 364.40 seconds ~ 1.75
>> Mpps ~ 2.6Gbit/s for a single process to get its data transmitted.
>>
>>
>>
>>
>>
>> Does anyone has any idea what I am doing wrong here ? In the second test
>> I would expect P1 to transmit with the same speed as in the first test. It
>> seems that there is a bottleneck somewhere, however. I have left most
>> things to their default values but have also tried tweaking queue sizes,
>> number of queues, interrupts, etc. with no luck
>>
>>
>>
>>
>>
>> Best Regards,
>>
>> Jesper
>>
>
>


More information about the users mailing list